Let’s talk

Dwell Wild

Health Community Land

ThreshEarlier work of our team
Learn

Planning a home on land

How do you build a house to withstand hurricanes, tornadoes and humidity?

Published Sep 26, 2026 · 7 min read

To build a house in the South that stands up to hurricanes, tornadoes and humidity, tie the roof down through the walls to the foundation, and protect windows and glass doors from flying debris where the code requires it. Against humidity, close the crawl space under the floor and give the walls a way to drain the rain that gets behind the siding. No house is hurricane-proof or tornado-proof, and FEMA warns that even one built to resist strong wind won't reliably protect the people inside from the strongest storms, so plan a safe room, a room built to FEMA's standard against extreme wind.

A raised wood cottage with a metal hip roof and wraparound porch under storm clouds, with wind arrows sweeping over it and a solid brick skirt closing in the crawl space.

A house built to code is built for a set wind speed, and no house is hurricane-proof or tornado-proof

Building codes require a house to withstand a set wind speed, called its design wind speed. Under the 2024 International Residential Code, a model code that states adopt, often with changes of their own, FEMA's safe room guide says that wind is 104 to 115 mph for a typical house in most inland tornado country, and 115 to 180 mph in hurricane-prone areas (FEMA P-320). Tornadoes and hurricanes "can cause winds much stronger" than that, and FEMA warns that even homes with "enhanced wind-resistant features" won't reliably protect the people inside from strong tornadoes or hurricanes that throw "wind-borne debris capable of penetrating walls, roofs, windows, and doors."

FEMA notes that state and local codes "are often multiple cycles behind the latest model codes," several editions older (FEMA P-320), so ask your county's building department what design wind speed its code sets for your land.

Nashville, Memphis, Birmingham and Montgomery sit in FEMA's highest tornado zone, where its guide calls a safe room "the preferred method of protection from extreme winds" (FEMA P-320).

Build the house to resist the design wind speed your county's code sets, and plan a safe room for the strongest storms.

A roof needs a sealed, well-nailed roof deck and a tie through the walls to the foundation

A section from roof edge to footing showing wind lifting under the eave and a chain of metal ties, a wall strap and an anchor bolt holding the roof down to the concrete foundation.

A roof needs a strong edge and a sealed, well-nailed roof deck (the wood boards under the shingles). "Roof damage often begins when wind gets underneath the roof edge and begins ripping it away from the home," says IBHS, an insurance-industry research group (IBHS). Its FORTIFIED Roof standard calls for a wider drip edge (the metal strip along the roof's border) and sealed seams on the roof deck. IBHS says sealed seams can cut the water that gets in when shingles blow off by up to 95 percent, and that ring-shank nails, which have ridges that grip the wood, nearly double the roof's strength against wind.

A hip roof slopes down on all four sides, and a gable roof has two slopes with a triangular wall at each end. In wind tunnel tests cited by the Department of Energy (DOE), the strongest wind pressures on a hip roof can be as much as 50 percent lower than on a gable roof, making hip roofs "a better choice for high-wind regions" (US DOE). The department calls gable roofs "prone to damage from uplift and racking in high winds," the roof lifted and the frame pushed sideways out of shape, and says to "brace gable ends."

Florida's emergency management agency says a house needs "a continuous load path," a chain of straps and other connections from the roof down through the walls into the foundation (Florida Division of Emergency Management). The agency warns that "it is not enough to just connect the roof to the tops of the walls."

Against hurricane winds, seal and nail the roof deck well, as IBHS advises, and tie the roof through the walls to the foundation, as Florida's emergency agency advises.

Near the coast and where the design wind is strongest, the code requires impact-protected windows and glass doors

A house by the shore with impact-rated glass in one window and its sliding door and storm panels over standard glass in the others, since near the coast or where the design wind is 140 mph or more every window and glass door must be protected.

The residential code requires the glass in outside walls in a windborne debris region to be "protected from windborne debris" (residential code, R301.2.1.2). FEMA's map puts Alabama's Gulf coast and the whole Florida peninsula in the hurricane-prone region. Florida's code draws the debris region within it, near the shore and wherever the design wind speed reaches 140 mph or more (Florida Building Code). Outside the debris region, FEMA notes, the code requires no debris protection on windows and glass doors (FEMA P-320).

Broward and Miami-Dade counties, Florida's High-Velocity Hurricane Zone (Florida Building Code), are strictest. There, FEMA says (FEMA P-320), every outside door and wall must resist a 9-pound 2x4 board flying at 34 mph, while a safe room's walls are built to resist a 15-pound 2x4 at 100 mph, so even the strictest code requires outside walls to stop a lighter, slower board than a safe room must.

Near the shore and wherever the design wind speed is highest, the residential code requires windows and glass doors protected from flying debris, so ask your county whether your land is in that region.

Without a basement, a safe room built to FEMA's standard is just as safe above ground

A cutaway of a framed house on a slab with a reinforced concrete block room inside, its steel door shut and its base bolted to the slab while wind blows through the frame around it.

A safe room that meets FEMA's design standard is "just as safe" above ground as below, FEMA's safe room guide says (FEMA P-320). A house on a concrete slab poured on the ground can still have a safe room, and the guide names two conditions that can rule out a room below ground: flood hazards and "a naturally high groundwater table," water close under the ground.

In a mapped flood area, the guide says (FEMA P-320), a safe room can't go below ground or below the flood level the county sets, and "storm shelters and safe rooms are not allowed in floodways under any circumstance." A floodway is the creek or river channel and the land beside it that must stay open for floodwater to pass, and flood maps are explained in our read on buying land. In the hurricane-prone region, FEMA recommends that families follow evacuation orders even if they have a safe room.

Our read on blackouts explains how a closet, interior bathroom or storage room can be built as a safe room.

A safe room built to FEMA's standard is just as safe above ground as below, so a house on a slab, or on ground too wet for a basement, can still have a safe room.

In the humid Southeast, a closed crawl space stays far drier than a vented one

Two crawl spaces side by side: on the left, damp air blows through a wall vent and moisture drips from moldy joists over bare dirt; on the right, a sealed space with no vents, a white liner over the ground and a dehumidifier.

A vented crawl space, the low space under a raised floor, has openings in its walls to the outside. A closed one, also called sealed or encapsulated, has no vents. All three states in this post fall in the Department of Energy's humid climate regions (US DOE).

Advanced Energy, in a study for the Department of Energy, compared crawl spaces under 12 houses with the same floor plan on one street in the southeastern US (Advanced Energy for US DOE). Through the humid summers, the closed crawl spaces had "much lower" humidity and drier wood than the vented ones. In the closed crawl spaces, moisture tended to follow the conditions inside the houses; in the vented ones it followed the humid weather outside. The houses with closed crawl spaces used more than 15 percent less energy for heating and cooling.

Tennessee's residential code allows a vented crawl space or a sealed one, and a sealed one needs a sealed liner over the ground and a way to dry its air, such as a small supply of air from the house's heating and cooling, or a dehumidifier (residential code, R408).

For a client building in Florida, I recommended sealing the crawl space: "I think you'd want to encapsulate under there." A crawl space also makes plumbing easier to fix, since with a slab "you have to bust up the concrete in order to access anything below that."

In a study for the DOE of 12 houses on one street in the humid Southeast, closed crawl spaces stayed much drier than vented ones, and their houses used more than 15 percent less energy for heating and cooling.

Outside walls need flashing and a way to drain the rain that gets behind the siding

A cutaway of an outside wall around a window, showing the house wrap lapped like shingles, metal flashing over the head and a pan under the sill, and rain behind the siding draining out at the bottom.

The residential code requires a water-resistant layer behind the siding on outside walls and a way for rain that gets behind it to drain back out (residential code, R703). It also requires flashing, strips of thin metal or membrane over windows, doors and roof edges, each piece laid over the one below it the way shingles overlap, to keep water out of the wall. Flashing works the same way on a roof: at Thresh Architects, in Tennessee, our design for the Wild Cabin sets each skylight on a raised frame with a factory flashing kit.

For the client building in Florida, I recommended cold-formed steel framing, wall frames made of thin sheet steel, because "it's just too hard to get wood right and not have it mold." Wood can work with "a good contractor who knows what they're doing" and details drawn properly, and the steel's price varies: "Sometimes it's more expensive, sometimes it's the same price as wood."

How walls dry out, and how damp indoor air leads to mold, are in our read on indoor air.

The code requires outside walls to have a water-resistant layer behind the siding, flashing over openings, and a way for rain that gets behind the siding to drain out.

Tennessee, Alabama and Florida each set their building codes their own way

Tennessee, Alabama and Florida each set their codes their own way, so ask your county's building department which code applies to your land.

Sources

  1. FEMA P-320, "Taking Shelter from the Storm: Building or Installing a Safe Room for Your Home", 6th edition, December 2024
  2. IBHS, "FORTIFIED Roof"
  3. US DOE Building America Solution Center (PNNL), "Hip Roof vs. Gable Roof"
  4. Florida Division of Emergency Management, Hurricane Retrofit Guide, "Walls"
  5. International Residential Code with Tennessee's amendments, chapter 3, Building Planning, on UpCodes
  6. Florida Building Code, Residential, 8th edition (2023), chapter 2, Definitions, on UpCodes
  7. Advanced Energy for the US DOE, "A Field Study Comparison of the Energy and Moisture Performance Characteristics of Ventilated Versus Sealed Crawl Spaces in the South", 2005
  8. International Residential Code with Tennessee's amendments, chapter 4, Foundations, on UpCodes
  9. International Residential Code with Tennessee's amendments, chapter 7, Wall Covering, on UpCodes
  10. US DOE and PNNL, Building America Best Practices Series Vol. 7.3, "Guide to Determining Climate Regions by County", 2015
  11. University of Tennessee County Technical Assistance Service, "Opt Out of Statewide Building Code Standards for One-Family and Two-Family Dwellings"
  12. Alabama Housing and Community Resilience, "Alabama Energy Codes"
  13. Strengthen Alabama Homes, Alabama Department of Insurance
  14. Florida Statutes § 553.73, Florida Building Code
  15. Florida Building Commission