I built an addition or second story without a permit in Manatee County. How do I get it permitted?

To permit an addition or second story built without a permit in Manatee County, Florida, you apply for an after-the-fact permit, a permit for work that's already built. Florida's building code treats an addition as new work, and Manatee County asks for drawings of what's there, sealed (signed and stamped) by a Florida architect or engineer, with the addition's same square footage on the permit application as on those plans. On every after-the-fact job in Thresh Architects' files, the county asked for at least one round of changes, so expect to revise the plans at least once. In my experience a private provider, an inspector the owner hires, does the inspections.

This post is for homes in unincorporated Manatee County (outside the limits of any city or town), where Manatee County Development Services issues the permit (Manatee County). If your home is inside the City of Bradenton, Palmetto, Holmes Beach, Anna Maria or Bradenton Beach, or the Town of Longboat Key, your city's or town's building department handles it (Bradenton, Palmetto, Holmes Beach, Anna Maria, Bradenton Beach, Longboat Key). A Bradenton or Palmetto mailing address doesn't settle it: on our jobs, homes with those addresses were outside city limits, so their permits went through the county. Check whether your lot is inside city limits.
An addition must meet the code for new work, and so must the part of the old house it rests on
Florida's building code says an addition "shall comply with the Florida Building Code as adopted for new construction," without making the existing house meet today's code (Florida Building Code, Existing Building, Chapter 11). One exception is where an addition "impacts the existing building or structure," and there "that portion shall comply." For a second story, that's the part of the house it rests on, so we usually have a structural engineer check that the house below can bear its weight.
Manatee County's house permit checklist asks for plans "signed/sealed by a registered Florida design professional" and a survey, a surveyor's sealed drawing of where the property lines are. It also lists a "Geotechnical Soil Report (New Construction or Additions)," a report on the soil under the building.
In 2026 we drew plans for two Manatee County homes with unpermitted additions, meaning additions built without a permit: a rear addition partly built onto a house, and, after a code enforcement letter, a second story built on top of a one-story house, with a covered back patio. Both follow the steps in our guide to the after-the-fact path: drawings of what's built, the permit application, zoning (the county's rules for what can be built where on a lot) and plan review (the county's check of the plans against the code), then inspections.
Plan for the addition to meet today's code in full, along with the part of the house it rests on or ties into.
The square footage on the application has to match the sealed plans
Manatee County's building permit application asks for the total square feet under roof, the conditioned square feet (the air-conditioned part) and the number of bedrooms, and it warns that the permit "may be revoked in the case of a false statement or misrepresentation in the application and/or plans."
For the rear addition's application, I had both numbers taken from the latest version of our drawings: the addition's conditioned area, and its gross area, meaning everything under roof measured to the outside face of the walls.
The bedroom count on the form comes from the drawings, because our drawings name what each room will be used for. A room drawn for sleeping has to meet the rules for sleeping rooms, such as a window big enough to climb out of in a fire (Florida Building Code, Residential, R310, as Pinellas County quotes it), which our post on garage enclosures explains.
Copy the addition's square footage onto the application from the sealed plans, because the county can revoke a permit for a false statement in the application or the plans.
Manatee County measures setbacks to the outside face of the wall

If an addition breaks the zoning rules, the drawings or the building may have to change. Manatee County's code says no structure "shall hereafter be built or moved on a lot which does not meet all of the minimum bulk and dimensional regulations" for its zoning district (Manatee County Land Development Code, 401.3). Those include the setbacks (how close a building may sit to each property line), and each zoning district sets its own.
On the rear addition, our drafter caught that the setbacks had been drawn to the roof's edge, but Manatee County measures setbacks to the outside face of the wall, so I redrew them. The code lets the eave, the roof's overhang, if it's at least 8 feet above the ground, reach 3 feet into the required yard (the strip of lot inside the setback), but no closer than 5 feet to the lot line (Land Development Code, 401.3).
Look up your address's zoning on the county's zoning map (Manatee County).
In Manatee County, setbacks are measured to the outside face of the wall, and the eave may reach up to 3 feet into the required yard but no closer than 5 feet to the lot line.
The plans must change to show what was built, where it meets the code

The reviewer checks the plans against the code, and the private provider later inspects the building against the approved plans, so on work that's already built every note on the plans has to match what's there. Where what's built doesn't meet the code, the building has to change, and the plans show that fix. As I wrote to a mobile home owner in October 2026, "a private provider can only approve inspections on work that's built the way the plans show it." Because the inspector can approve only what they can see, part of a finished wall or ceiling may need opening to show the work behind it, which the guide explains.
On our second story, the plans didn't match what was built at the trusses, the triangle frames a roof is built on. Florida's code says truss design drawings "shall be provided to the building official" and "approved prior to installation" (Florida Building Code, Residential, R802.10.1).
The plans had an old note saying a truss company would supply the trusses, so the reviewer expected that company's drawings. The county's first comment was "Truss package," meaning the truss maker's drawings. I wrote to the owner, "We designed the trusses ourselves, and they are already in the plans." We removed the note, and the revised drawings say the trusses are "site-built" (built on the house by the framers, not in a truss factory).
Have the plans changed to show what was built, where what was built meets the code.
Plan review asks for missing papers and details, and each comment needs a written answer
The county wants a written answer to each comment in its online Plan Room, and only the changed pages of the drawing set (the sheets), with their sheet numbers kept, since the county's help page says changing the numbers delays the review (Manatee County).
Our second story drew five comments. Building review asked for four things: the truss package, the Florida product approvals, the energy calculations and a detail of the cricket, a small roof where the new wall meets the old one. The zoning reviewer asked whether the work added square footage, and we described what was new on each floor.
A Florida product approval number shows the state approved a product, such as a window or a roof, for use in Florida (F.S. 553.842). The county's checklist lists the products that need one, including every outside window, door, shutter, roofing and siding product, roof vent and exhaust fan, and the soffit (the underside of the roof's overhang).
The county also requires energy calculations, which show the new living space meets Florida's energy code (Florida Building Code, Existing Building, 1106.1). Clients almost never have them, so we arrange them, and someone outside our office prepares them.
A reviewer can also ask for something the plans left out, such as a construction detail (a close-up drawing of how it's built) of a cricket, placed so rain runs around the wall and off the roof instead of pooling against it.
In November 2026, the revised set and our answers went back.
Answer every comment in writing and send back only the sheets that changed, as the county asks.
On our Manatee jobs, a private provider who didn't draw the plans has done the inspections
As I've seen it, Manatee County doesn't inspect after-the-fact work itself, so the inspections go to a private provider. The law bars a provider from inspecting a building their own firm designed (F.S. 553.791). When the rear addition's owner asked me to inspect it, I wrote back that I couldn't, because "it would be a conflict of interest if I inspected and reviewed my own plans." Thresh Architects can be that provider when another firm drew your plans.
The private provider must come from a different firm than the one that drew your plans, and approves only work built the way the plans show it.
In a flood zone, ask the county who will inspect, and watch the 50% rule
If your house is in a FEMA flood zone (a Special Flood Hazard Area), the county's written policy says additions there "will be reviewed and inspected entirely by the Manatee County Building Division" (Manatee County). In my experience the flood rules add their own limits, such as the 50% rule below, but they don't replace the building inspections, and on after-the-fact work those have still gone to a private provider. Because its written policy says otherwise, ask the county at the start who will inspect yours.
The county's 50% rule covers work whose cost, all added together over one year, "equals or exceeds fifty (50) per cent of the market value of the building" (Manatee County). From what I've seen, at that line the whole house must meet today's flood rules, "including elevating the building" (Manatee County), which an older house usually can't, so it may have to come down.
Unless you bring a qualified independent appraisal (a report on what the building is worth), the county uses the county property appraiser's value for the building (Manatee County), so on an addition already built, an appraisal that values the building higher can keep the cost under half.
In a flood zone, keep the cost of the work under half the building's value, because at half or more the whole house must meet today's flood rules.
Sources
- Manatee County, "Apply, Search and Manage Building Permits"
- City of Bradenton, Building and Permitting Division
- City of Palmetto, Building Department
- City of Holmes Beach, Building Department
- City of Anna Maria, "Frequently Asked Questions"
- City of Bradenton Beach, Building & Planning
- Town of Longboat Key, Building Division
- Florida Building Code, Existing Building 2023, Chapter 11, Additions (UpCodes)
- Manatee County Development Services, "One & Two Family Submittal Checklist"
- Manatee County, Building Permit Application
- Pinellas County, "2023 Florida Building Code" (emergency escape and rescue openings, Section R310)
- Manatee County Land Development Code (Municode), Section 401.3
- Manatee County, "Planning Maps" (zoning lookup, Feb 24 2025)
- Florida Building Code, Residential 2023, Chapter 8, Roof-Ceiling Construction (UpCodes)
- Florida Statutes § 553.842, product approval
- Manatee County, Access the Digital Plan Room Help Center
- Florida Statutes § 553.791, private providers
- Manatee County, "Private Provider Program, Projects in a FEMA Special Flood Hazard Area"
- Manatee County, Flood information
- Manatee County, "Determination of Improvement" form
- Manatee County, "Floodplain Post Storm Guidance" (Feb 12 2025)
Let’s talk